Losses in Glint Solar vs. losses in PVsyst
The table below shows how losses recorded in Glint Solar correspond to losses recorded in PVsyst.
| Glint Solar | PVsyst | Notes |
| Meteo data base | Meteonorm 8.2.0.21236 | |
| Horizon shading | Farshading loss (only in losses diagram) | |
| Dirt and soiling | Soiling loss | |
| Near shading: irradiance loss | Shading loss | |
| Reflection (IAM) | IAM loss (only in losses diagram) | |
| Bifaciality | - | In PVsyst, "bifaciality" is the performance factor of the back side relative to the front side. For example, if the bifaciality is 0.7, this means that the back side will be 70% as good as the front side. In Glint Solar, "Bifacial gain" instead corresponds to the bifacial gain, which is displayed as a gain in the loss diagram in PVsyst. |
| Irradiances dependencies | - | Glint Solar does not explicitly state how much is lost due to low irradiation levels. However, this is taken into account in the conversion of irradiation into electricity. |
| Near shading: electrical loss according to strings | Electrical losses due to shading (only in losses diagram) | |
| Power tolerance of modules | Nameplate rating loss | |
| Temperature dependencies | Temperature loss (only in losses diagram) | |
| Spectral correction | Spectral correction (only in losses diagram) | |
| Light induced degradation (LID, initial) | Light-induced degradation | |
| Mismatching Modules | Mismatch losses | Match losses due to shading are calculated in "electrical losses due to shading" in Glint Solar. |
| Mismatching Strings | ||
| Mismatching back face | ||
| DC cabling | Wiring losses | Glint Solar captures "connection losses". Connection losses are the losses between cabling and diodes. |
| AC cabling | ||
| HTA cabling | ||
| Transformer | Glint solar does not yet support transformers. | |
| Inverter | Inverter | Only in the pattern of losses. It is not possible to make inverter losses. |
| Auxiliaires | - | Glint Solar has no โauxiliaryโ losses. To add these losses, you can add the losses to other loss categories (fouling or conductors). |
| Additional | - | Glint Solar does not have an "other" loss category. |
| Unavailability of the system | Availability Loss | |
| Vieillissement | Annual Degradation | |
| Albedo | Albedo 0,2 |
Research project with IFE
If you're interested in learning more about our research project with IFE and how we compare with PVSyst, read the report here:
๐งฎ Comparison between the Glint Solar PV model and PV syst
Additional resources
Learn more about the losses recorded in Glint Solar here.
You can also read about the methodologies used for the simulation here.
Are you looking for some more guidance on the PV concepts? Check out our Solar Site planning guide!